Yokogawa enhances GA10 Data-logging Software with OPC | Automation.com

Yokogawa enhances GA10 Data-logging Software with OPC

January 222015
Yokogawa enhances GA10 Data-logging Software with OPC

January 21, 2015 - Yokogawa Electric  updated GA10 data-logging software for the SMARTDAC+ data acquisition and control system. Enhancements in Release 2.0 include  real-time calculation and report output functions, and  the OPC-UA industrial communications protocol.

GA10 is a PC based data-logging program that is used in the development and production processes in many different industries to collect, display, and record temperature, voltage, current, flow rate, pressure, and other types of data from instruments such as recorders, temperature controllers, and power meters. With this software, a system can be built to collect data from Yokogawa data acquisition and recording devices and measuring instruments as well as third-party devices that support the Modbus general-purpose industrial communications protocol, eliminating the need for advanced, but expensive system solutions such as SCADA software and DCSs. GA10 is widely used to construct systems for the monitoring and recording of data. This enhanced version of the GA10 software offers the following optional functions that satisfy the needs of customers who need not only to collect data from multiple sources but also display the results of calculations and quickly create reports from this data.

GA10 release 2 has a function that can perform calculations using data from multiple channels and display the results in real time. No special knowledge of computer programming is required: users need only to enter a formula for the calculation in a spreadsheet cell. One typical application is the development of household appliances such as air conditioners, which requires the display of temperature readings from multiple locations.

While the earlier version of the GA10 software can print tables containing data from multiple sources, GA10 release 2 can also print reports that contain graphs, text, and images. This function allows users to customize their reports for purposes such as filing to government authorities and reporting on product evaluation tests for their customers. To output these reports automatically, users only need to set the report format and time, thus greatly improving efficiency.

For improved connectivity with other companies’ SCADA systems and higher-level databases, GA10 release 2 supports the OPC-UA industrial communications protocol. As a result, a greater variety of host systems can now access data collected by plant facility monitoring systems that utilize data acquisition and recording devices and the GA10 release 2 software or which has been stored in databases using the GA10 release 2 software.