• ISA provides technical resources and standards to help industrial automation professionals advance their careers and the field. We enable automation professionals worldwide to solve problems and enhance their skills by bringing people together to create new technologies and share best practices with future automation professionals.
    • Industry Insights

  • We attract over 140,000 unique automation professionals monthly, making us the premier online content provider and the only dedicated electronic magazine in the automation industry.

    Monthly Magazine

    • More things to read

    Back
    Back
  • M logo for Automation.com Monthly. Link to current issue.

Burkert Introduces New Mass Flow Devices

Source: Burkert Contromatic Inc.
17 November, 2005
2 min read

Type 8712 Mass Flow Controller

The Type 8712 Mass Flow Controller (MFC) handles neutral, non-contaminated gases at flow rates as low as 20 cm3N /min and as high as 50 lN/min. This MFC offers automation professionals response times as rapid as 300 ms, with standard turn-down ratios of 1/50 (1/500 in special circumstances).To attain these extraordinarily fast times — 4X faster than those achieved with conventional gas flow meters — the Type 8712 employs patented CMOSens® technology. This technology, enabling sensing of the smallest amounts of gas flow, embeds a heater element in the Type 8712’s bypass capillary tube. It also places two temperature sensors in the tube, one upstream and one downstream of the heater element.

As a gas stream passes through the tube, directly contacting the heater element and a measuring chip, the measured difference between the two temperature sensors allows relationship to flow to be determined in a fraction of a second.The Type 8712 outputs measured values at an accuracy of ±1 percent of Rdg., ±0.5 percent full scale. Linearity is ±1 percent full scale.

Type 8712 repeatability is ±0.5 percent full scale, while maximum operating pressure (inlet pressure) is 145 psi, depending on nominal valve diameter. Fieldbus communications capabilities include PROFIBUS-DP and DeviceNet (others upon request).The Type 8712 features an output signal of 0-5V, 0-10V, 0-20mA or 4-20mA.

With a stainless steel body, the unit measures approximately 4.5 x 5.5 x 1.5 inches and weighs less than three pounds

Type 8702 Mass Flow Meter

Like the Type 8712, the Type 8702 Mass Flow Meter employs CMOSens® technology. Flow rates range from 20 cm3N/min to 50 lN/min, with an optional low-flow rate as low as 0.04 cm3N/min.

Accuracy is ±0.8 percent o.R./±0.3 percent F.S., linearity is ±0.1 percent F.S., and repeatability is ±0.1 percent F.S.

Response time is <300 ms.

Type 8626 Mass Flow Controller

The Type 8626 features flow rates from 25 lN/min to 1500 lN/min. This unit permits a constant gas flow or flow following a pre-defined set-point profile unaffected by interference (e.g. pressure variations).

Accuracy is ±1.5 percent of rate/±0.3 percent F.S., linearity is ±0.25 percent F.S., and repeatability is ±0.1 percent F.S.

Settling time is <500 ms.

Type 8006 Mass Flow Meter (inline)

The Type 8006 features flow rates from 25 lN/min to 1500 lN/min, and a response time of <500 ms.

Accuracy is ±1.5 percent of rate/±0.3 percent F.S., linearity is ±0.25 percent F.S., and repeatability is ±0.1 percent F.S.

A special version of this unit can be used with ammonia gas.For more information on any of the above products, please visit www.burkert-usa.com .