• ISA provides technical resources and standards to help industrial automation professionals advance their careers and the field. We enable automation professionals worldwide to solve problems and enhance their skills by bringing people together to create new technologies and share best practices with future automation professionals.
    • Industry Insights

  • We attract over 140,000 unique automation professionals monthly, making us the premier online content provider and the only dedicated electronic magazine in the automation industry.

    Monthly Magazine

    • More things to read

    Back
    Back
  • M logo for Automation.com Monthly. Link to current issue.

Endress+Hauser announces Liquiline System CA80HA hardness analyzer

By: Endress+Hauser, Inc.
31 July, 2019
Endress+Hauser announces Liquiline System CA80HA hardness analyzer
Endress+Hauser announces Liquiline System CA80HA hardness analyzer
The CA80HA colorimetric analyzer uses the phthalein purple method, for direct comparability to lab results. It measures calcium carbonate (CaCO3) over a range of 0 to 80 mg/l with accuracy of ±0.5 mg/l.

July 30, 2019—Endress+Hauser announces the Liquiline System CA80HA hardness analyzer to provide online analysis of water hardness in drinking water and process water. It helps optimize the control of water softening processes such as ion exchange or reverse osmosis, and works to ensure quality of products influenced by water hardness, and analyzes feedwater used in boilers.

The CA80HA colorimetric analyzer uses the phthalein purple method, for direct comparability to lab results. It measures calcium carbonate (CaCO 3 ) over a range of 0 to 80 mg/l with accuracy of ±0.5 mg/l. The analyzer has up to two measuring channels and up to four digital inputs for optional Memosens sensors such as pH, ORP, conductivity, oxygen, chlorine, turbidity, etc.

With optional sensors, it can:

  • Measure and calculate pH from two conductivity values according to VGB Standard 405 for boiler feedwater
  • Measure the difference between two measured values from different sources to monitor membranes
  • Calculate differential conductivity to monitor the efficiency of ion exchangers
  • Calculate degassed conductivity for process controls in power plants
  • Calculate rH from the measured values of a pH and an ORP sensor

Outputs from the CA80HA can be used to directly control water processes as the process variables in a control loop, be assigned as a measured variable to a limit contactor, trigger cleaning, be sent to a control system for further analysis, and/or be displayed on the local graphic readout. The local graphic display has 240 x 160-pixel resolution, a red display background for alarms and user-definable measuring menus.

Outputs include PROFIBUS DP (Profile 3.02), Modbus TCP, Modbus RS485, EtherNet/IP and up to four 4-20mA current outputs that can be used in parallel.