Mass Flow Meter Summary:
The ST50 Series Flow Meters are an accurate, easy to install, no moving parts mass flow meter solution. Model ST50 is used for compressed air and nitrogen flow. Model ST51 is used for measuring biogas, digester gas, methane and natural gas. The ST50 Series utilizes FCI proven thermal dispersion technology to provide direct mass flow measurement resulting in higher performance at a lower cost than orifice plates, DP, Vortex shedding and other thermal devices. The meter installs in line sizes ranging from 2 to 24 inches [51 to 610mm] with 1/2" or 3/4" NPT.
The ST50 Series uses precision, lithography structured platinum RTD sensors embedded in FCI's equal mass small diameter, all metal thermowells. Combined with microprocessor electronics and precision calibration, the ST50 achieves excellent accuracy, fast response and virtually maintenance free operation.
-
Wastewater Treatment Aeration Control
-
Blower and Dryer Air Flow Control
-
Burner and Furnace Air Flow Control
-
Lake, Pond and Aquaculture Aeration
-
HVAC Duct/Damper Control
-
Compressed Air Distribution Measurements
-
Landfill Gas Recovery (LMG)
-
Wastewater Treatment Plant Digester
-
Coal Mine Methane Recovery
-
Livestock and Dairy Farm On-Farm Biogas Recovery
-
Biogas: Biomass Fermentation and Recovery
-
Biomass Gasification
Specifications:
Model ST50 |
Model ST51 |
|
Media Compatibilty |
Air, Compressed Air, Nitrogen |
Biogas, Digester Gas, Methane, Methane Composition Gases, Natural Gas, Air, Compressed Air, Nitrogen |
|
Agency Approvals
FM/CSA: |
Class 1, Div.2, Groups A,B,C,D; T4 |
Class 1, Div.1, Groups B,C,D, Class 1, Div.2, Groups A,B,C,D; T4 |
ATEX: |
Zone 2II 3 G EEx nA IIT6II 3 D T65C |
Zone 1II 2 G Ex d IIC T6...T3, II 2 D Ex tD A21 IP67T90°...T300° |
|
Output Signals
Dual 4-20 mA Analog:0-500 Hz pulse for totalizer: |
YesOptional |
YesYes |
Digital Display(optional) |
LCD, ±9999 counts, user scaleable to flow rate engineering units or 0-100% |
LCD, 2 line x 16 Characters. First line is flow rate and engineering units. Second line user selectable as temperature or flow totalizer, or alternating. |
Pipe/Line Size Compatibility:
2" to 24" [51 mm to 610 mm]
Flow Rate:
-
ST50: 0.75 to 400 sfps [0.23 to 122 mps]
-
ST51: 0.3 to 400 sfps [0.08 to 122 mps]
-
Standard: ± 2% reading, ± 0.5% full scale
-
Optional: ± 1% reading, ± 0.5% full scale
-
Standard: 40° to 100° F [4° to 38° C];
-
Optional: 0° to 250° F [-18° to 121° C]
·Stainless steel ferrule: 500 psig [34 bar(g)]
·Teflon ferrule: 150 psig [10 bar(g)]
-
Stainless steel ferrule: 0° to 250° F [-18° to 121° C]
-
Teflon ferrule: 0° to 200° F [-18° to 93° C]
-
1 to 6 inches [25 to 152 mm]
-
1 to 12 inches [25 to 305 mm]
-
1 to 18 inches [25 to 457 mm]
-
DC:18 to 36 Vdc
-
AC:85 to 265 Vac (CE Mark Approval from 100 to 240 Vac).