• ISA provides technical resources and standards to help industrial automation professionals advance their careers and the field. We enable automation professionals worldwide to solve problems and enhance their skills by bringing people together to create new technologies and share best practices with future automation professionals.
    • Industry Insights

  • We attract over 140,000 unique automation professionals monthly, making us the premier online content provider and the only dedicated electronic magazine in the automation industry.

    Monthly Magazine

    • More things to read

    Back
    Back
  • M logo for Automation.com Monthly. Link to current issue.

ProSoft Technology releases HART analog input gateway

By: ProSoft Technology, Inc.
29 September, 2008
ProSoft Technology releases HART analog input gateway
ProSoft Technology releases HART analog input gateway
HART Analog Input gateway integrates HART instruments with existing controller platforms over Modbus TCP/IP, EtherNet/IP and DF1 networks.

September 29, 2008 - ProSoft Technology's HART Analog Input gateway provides a clean way to integrate HART instruments with existing controller platforms over Modbus TCP/IP, EtherNet/IP and DF1 networks. The gateways are available in four and eight channel options, where each channel is individually configurable and structured for point-to-point communication, thus ensuring the fastest possible update times (67 milliseconds) from HART field devices as opposed to methods which scan the HART channels.

Applications

There are 20 million HART smart field devices installed worldwide. The HART Analog Input gateways are ideal for factory automation and process applications that need to expedite data retrieval from these devices, particularly where the devices are not located near the controller. The gateway allows the HART Master to be placed close to HART instruments in order to minimize material and installation costs associated with running copper cable to a controller cabinet. The gateway also has an onboard power supply and requires no additional purchase to operate.The HART Analog Input gateway can monitor variables such as flow, temperature, pressure, and PH, and are additionally able to read and write to digital data such as reading device firmware revisions.

HART Analog and Multi-Drop

The primary difference between HART multi-drop and HART Analog is the tradeoff of volume for speed, respectively. For high volume applications, ProSoft Technology’s HART Multi-drop products are ideal, allowing up to 120 HART devices to be installed on the same current loop. HART Analog Input is point-to-point, so with the HART Analog Input gateways, each HART channel can connect to a single field device, ensuring optimal signal speeds from the devices. HART Analog is backward-compatible with most existing analog I/O systems, and is faster than any other field communications protocol, with almost instantaneous response time from the 4-20mA analog signal, depending upon the signal dampening built into the system.

Features:

  • Extremely fast data refresh: independent HART channels update simultaneously at 67 milliseconds.
  • Individual channel isolation: upon failure of one channel, the other channels will continue to operate.
  • Integrated 24 VDC current loop power supply: allows convenient and trouble free setup.
  • Overvoltage protection with resettable in-line fuse: A gas discharge tube and surge arrestors are included for lightning protection.
  • Support for Explicit Messaging (Ethernet/IP gateway only)
  • EtherNet/IP and Modbus TCP/IP ports are user-configurable as either a Client or a Server, and the DF1 port is configurable as a Master or a Slave.