• ISA provides technical resources and standards to help industrial automation professionals advance their careers and the field. We enable automation professionals worldwide to solve problems and enhance their skills by bringing people together to create new technologies and share best practices with future automation professionals.
    • Industry Insights

  • We attract over 140,000 unique automation professionals monthly, making us the premier online content provider and the only dedicated electronic magazine in the automation industry.

    Monthly Magazine

    • More things to read

    Back
    Back
  • M logo for Automation.com Monthly. Link to current issue.

WAYJUN introduces RS485 to 4-20mA,RS232 to 0-5V, D/A Converters

Source: Shenzhen WAYJUN Industrial Automation
03 June, 2014
1 min read
With Modbus, RS485/232 to Analog Current or Voltage Signal Converters, 12-bit DA converter, analog signal output accuracy>0.2%

FeaturesÔºö

>>DIN Rail-mounted >>RS485/232 to 4-20ma/0-5V analog signal output >>12-bit DA converter,analog signal output accuracy>0.2% >>Can be remotely reconfigured for modules accuracy >>Three-port Isolation: 3000VDC isolation. >>Wide power supply range:8~32VDC >>High reliability, easy program, installation. >>Can program setting module address, baud rate >>Support Modbus RTU

ApplicationsÔºö

>>Intelligent building control, security and engineering applications >>RS485/232 industrial automation control system >>Industrial fields signal isolation and long-terms transmission >>Debugging and control of equipment operation >>4-20mA signal output >>Medical machine monitoring >>Sensor signal to restore the long-range transmission and signal >>Industrial field data for a given actuator

Function DescriptionÔºö

WJ31 signal isolated D/A converter module, can output one channel voltage/current signals,or 2-channel common ground and isolation current/voltage signals.

Product Selection:

WJ31

‚ñ° – 

U(A)

‚ñ°

Interface Output Voltage or Current Signal

485

:Input is RS-485 interface U1Ôºö0-5V A1Ôºö0-1mA

232

:Input is RS-232 interface U2Ôºö0-10V A2Ôºö0-10mA

U3Ôºö0-75mV A3Ôºö0-20mA

U4Ôºö0-2.5V A4Ôºö4-20mA

U5Ôºö0-±5V A5Ôºö0-±1mA

U6Ôºö0-±10V A6Ôºö0-±10mA

U7Ôºö0-±100mV A7Ôºö0-±20mA

U8Ôºöuser-defined A8Ôºöuser-defined

Sample 1: part No

. :

WJ31 485-A4

Input is RS485 interface,4-20mA signal output

Sample 1: part No

. :

WJ31 232-U1

Input is RS-232 interface ,0-5Vsignal output

General parameters:

(typical @ +25 ‚ÑÉ, Vs to 24VDC)

Output type: current / voltage signal

Accuracy: 0.2%

Output maladjustment: current output ± 0.5 uA / ° C, voltage output of ± 0.1 mV / ° C

Temperature drift:±20 ppm / ‚ÑÉ(±30 ppm / ‚ÑÉ, maximum)

Output load capacity: current output 350Ω (4-20mA/0-20mA/0- ± 20mA current output)

voltage output 10mA (0-5V/0-10V/0- ± 5V voltage output)

Communication: RS-485 protocol or RS-232 standard characters protocols and MODBUS RTU communication protocol

Baud Rate (1200,2400,4800,9600,19200,38400 bps) can be selected via software

Address (0 to 255) can be selected via software

Communication Response Time: 100 ms maximum

Power Supply: +8 ~ 32VDC wide range power supply, internal anti-reverse and over-voltage protection circuit

Power Loss: less than 1.5W

Operating Temperature: - 45 ~ +80 ‚ÑÉ

Humidity: 10 ~ 90% (no condensation)

Storage Temperature: - 45 ~ +80 ‚ÑÉ

Storage Humidity: 10 ~ 95% (no condensation)

Isolation Voltage: communication interface / output: 3KVDC, 1 minute, leakage current:1mA