• ISA provides technical resources and standards to help industrial automation professionals advance their careers and the field. We enable automation professionals worldwide to solve problems and enhance their skills by bringing people together to create new technologies and share best practices with future automation professionals.
    • Industry Insights

  • We attract over 140,000 unique automation professionals monthly, making us the premier online content provider and the only dedicated electronic magazine in the automation industry.

    Monthly Magazine

    • More things to read

    Back
    Back
  • M logo for Automation.com Monthly. Link to current issue.

Axiom Analytical releases FDR-1800 near-infrared probe

25 February, 2009
FDR-1800 probes can be fabricated in virtually any length for process monitoring in full-scale batch reaction vessels.

February 24, 2009 – Axiom Analytical announced its FDR-1800 Series Near-IR Diffuse Reflectance Probes. The probes can be fabricated in virtually any length and thus provide a unique capability for process monitoring in full-scale batch reaction vessels. Such vessels often include glass lining or heating coils, making probe entry from the side of the vessel impossible. However, an FDR-1800 probe can be made long enough for top entry even in the largest reaction kettles.

An important feature of the FDR-1800 design is the use of Axiom’s proprietary window sealing technique involving a direct sapphire to metal welded pressure seal (U.S. Patent 6,587,195 B1). This approach provides significant advantages over other sealing techniques. A high degree of chemical resistance is assured by the fact that the only materials in contact with the process are sapphire, high nickel alloys, and a thin flash of either gold or PTFE (application dependant).

The compliance required to withstand extreme temperature cycling is provided by the high nickel alloy seal which is compressed at high pressure prior to welding. This approach eliminates fatigue and stress failures common with brazed seals as well as the limited lifetime characteristic of elastomeric seals. The optical design of the FDR-1800 Series is highly efficient, providing high quality NIR diffuse reflectance data even for nearly opaque samples. In fact, good quality on-line data have been obtained with process fluids having a total reflectance of less than 2 %.

This performance is due both the efficiency of the optics and to a unique design which greatly reduces stray light due to reflectance within the probe (U.S. Patent 5,818,996).