• ISA provides technical resources and standards to help industrial automation professionals advance their careers and the field. We enable automation professionals worldwide to solve problems and enhance their skills by bringing people together to create new technologies and share best practices with future automation professionals.
    • Industry Insights

  • We attract over 140,000 unique automation professionals monthly, making us the premier online content provider and the only dedicated electronic magazine in the automation industry.

    Monthly Magazine

    • More things to read

    Back
    Back
  • M logo for Automation.com Monthly. Link to current issue.

Belden adds 2000 volt variable frequency drive cables

By: Belden
05 October, 2009
Belden adds 2000 volt variable frequency drive cables
Belden adds 2000 volt variable frequency drive cables
The 2000V UL 1277 Type TC-ER cables are UL rated for direct burial, feature black sunlight- and oil-resistant PVC jackets, and meet all applicable industry standards and specifications for VFD cables.

October 5, 2009 - Belden added 2000 Volt VFD cables to its line of Variable Frequency AC motor drive cables. 2000V VFD Cables added include: Classic Design VFD Cables, 14 to 2 AWG, with Beldfoil plus TC Braid Shield. Similar to Belden’s other classic VFD cables, this series of seven cables features oversized XLPE insulation to provide the lowest capacitance available in a VFD cable. Highly effective dual shielding provides the lowest resistance to ground path, which improves common mode current containment. The 85 percent braid coverage offers optimum EMI low frequency noise protection, while the 100 percent aluminum/Mylar tape shield offers RFI high frequency noise protection.

Also included in the smooth, round cables are full-size, insulated green ground wires with a yellow stripe and drain wires for ease of installation and termination. Symmetrical Design, Large AWG (1 to 4/0), with Spiral Copper Tape Shield. Similar to Belden’s other Symmetrical cables, this series of five cables combines the benefits of Belden’s classic VFD cables with additional features for use on larger, more powerful AC motor drives. Highly effective shielding provides a low resistance ground path, which improves common mode current containment. Spirally applied dual copper tape shields provide 100 percent coverage, coupled with improved flexibility and EMI/RFI noise protection.

Three symmetrical bare ground wires provide a balanced ground system to reduce the likelihood of premature motor bearing or motor insulation failure. All of Belden’s new 2000V UL 1277 Type TC-ER cables are UL rated for direct burial, feature black sunlight- and oil-resistant PVC jackets, and meet all applicable industry standards and specifications for VFD cables.