• ISA provides technical resources and standards to help industrial automation professionals advance their careers and the field. We enable automation professionals worldwide to solve problems and enhance their skills by bringing people together to create new technologies and share best practices with future automation professionals.
    • Industry Insights

  • We attract over 140,000 unique automation professionals monthly, making us the premier online content provider and the only dedicated electronic magazine in the automation industry.

    Monthly Magazine

    • More things to read

    Back
    Back
  • M logo for Automation.com Monthly. Link to current issue.

Encoder differential signal to pulse signal isolator

By: Shenzhen WAYJUN Industrial Automation
09 September, 2014
Encoder differential signal to pulse signal isolator
Encoder differential signal to pulse signal isolator
Differential encoder input signal is converted into a pulse signal directly

Keywords: Encoder | differential signal | pulse | isolated converter | Signal Conditioner

Features: 

>> Differential encoder input signal is converted into a pulse signal directly

>> Support A, B, and Z three-phase differential simultaneous conversion

>> 3 inputs, 3 outputs, selectable output pulse amplitude

>> No change the original waveform frequency, response speed is over 500KHz

>> Three-isolation:signal input/Power/signal output 3000VDC

>> Power supply: 5V, 12V, 15V or 24V DC single power supply

>> Low cost, high small size, ease of use, reliability

>> Standard DIN35 rail mounting

>> Dimensions: 120 mm x 70 mm x 43mm

>> Industrial Temperature Range: - 45 ~ + 85 ‚ÑÉ

Application: 

>> Encoder differential signal isolation, acquisition and conversion

>> Differential encoder 24V square wave pulse signal transduction

>> Servo encoder signals to the PLC differential

>> Pulse signal amplification and shaping

>> Ground interference suppression

>> Motor speed monitoring system

>> Speed ​​measurement and alarm

>> Signals without distortion transmission and transmission

Products Listing:
DIN33  IAP – S‚ñ° - P‚ñ° – O‚ñ° 
Input Signal
Power Supply
Output Signal
input
code

Power

code
output
code

24VDC

P1

output level 0-5V

O1

Single signal input,

peak value ( VP-P): 5V

S2

12VDC

P2

output level 0-12V

O2

Single signal input,

peak  value ( VP-P): 12V

S3

5VDC

P3

output level 0-24V

O3

Single signal input,

peak value ( VP-P): 24V

S4

15VDC

P4

Open collector output

O4

5v differential pulse signal input

S5

user-defined

Su

user-defined

Ou

samples:

1: Input: Encoder differential signal Power supply: 24V Output: 0-5V level

Type No.: DIN33 IAP-S5-P1-O1

2: Input: Encoder differential signal Power supply: 12V Output: 0-24V level

Type No.: DIN33 IAP-S5-P2-O3

3: Input: 0-5V level Power supply: 24V Output: 0-24V level

Type No.: DIN33 IAP-S2-P1-O3

4: Input: 0-5V level Power supply: 12V Output: open collector

Type No.: DIN33 IAP-S2-P2-O4

5: Input:user-defined Power supply: 24V Output: user-defined

Type No.: DIN33 IAP-Su-P1-Ou