• ISA provides technical resources and standards to help industrial automation professionals advance their careers and the field. We enable automation professionals worldwide to solve problems and enhance their skills by bringing people together to create new technologies and share best practices with future automation professionals.
    • Industry Insights

  • We attract over 140,000 unique automation professionals monthly, making us the premier online content provider and the only dedicated electronic magazine in the automation industry.

    Monthly Magazine

    • More things to read

    Back
    Back
  • M logo for Automation.com Monthly. Link to current issue.

GF Piping Systems introduces Signet 9950 Dual Channel Transmitter (Gen 2b)

By: GF Piping Systems
13 September, 2018
GF Piping Systems introduces Signet 9950 Dual Channel Transmitter (Gen 2b)
GF Piping Systems introduces Signet 9950 Dual Channel Transmitter (Gen 2b)
With the setup of a transmitter and the versatility of a controller, the 9950 Gen 2b fully supports the Signet 2751 pH/ORP Smart Sensor Electronics for pH/ORP measurements.

September 13, 2018 – GF Piping Systems has added the Signet 9950 Dual Channel Transmitter (Gen 2b) to its flow and analytical instrumentation product line. The 9950 Gen2b adds functionality to its capabilities that enable multiple measurement readings in one transmitter.

With the setup of a transmitter and the versatility of a controller, the 9950 Gen 2b fully supports the Signet 2751 pH/ORP Smart Sensor Electronics for pH/ORP measurements. Used together, they can transfer pH and ORP calibration data to the company’s 9900/2751, 9950/2751, or stand alone 2751 systems. Additionally, the 9950 Gen 2b automatically measures pH glass impedance, detects broken glass, and reads stored data in all Signet DryLoc pH and ORP electrodes.

Other features of the 9950 Gen 2b include support of two new plug-in modules – the Single Channel Direct Conductivity Module (3-9950.394-1) and the Dual 4 to 20 mA Current Loop Output Module (3-9950.398-2).

  • The 394-1 module is fully compatible with all Signet conductivity electrodes and can be used for conductivity/resistivity, and salinity measurements.
  • The second module, the 398-2, expands the number of passive current loop outputs previously available from 2 to 6 for measurement flexibility.

Plus, two single channel direct conductivity modules can be installed in a single 9950 transmitter.

Each current loop output can be set to the primary or secondary measurement of either channel, or to any of the derived functions.

Trending Articles

Advertisement

Related Industry Products

View all Industry Products
Advertisement
Advertisement