• ISA provides technical resources and standards to help industrial automation professionals advance their careers and the field. We enable automation professionals worldwide to solve problems and enhance their skills by bringing people together to create new technologies and share best practices with future automation professionals.
    • Industry Insights

  • We attract over 140,000 unique automation professionals monthly, making us the premier online content provider and the only dedicated electronic magazine in the automation industry.

    Monthly Magazine

    • More things to read

    Back
    Back
  • M logo for Automation.com Monthly. Link to current issue.

Improving performance using cascade control and a Smith predictor

By: ISA Transactions
16 January, 2012
1 min read
Improving performance using cascade control and a Smith predictor
Improving performance using cascade control and a Smith predictor
Improving performance using cascade control and a Smith predictor

This is from a series of articles reprinted from the journal ISA Transactions. All ISA Transactions articles are free to ISA members, or can be purchased from Elsevier Press.

Fig. 1. Block diagram of a cascade control system.

Abstract:

Many investigations have been done on tuning proportional-integral-derivative (PID) controllers in single-input single-output (SISO) systems. However, only a few investigations have been carried out on tuning PID controllers in cascade control systems. In this paper, a new approach, namely the use of a Smith predictor in the outer loop of a cascade control system, is investigated. The method can be used in temperature control problems where the secondary part of the process (the inner loop) may have a negligible delay while the primary loop (the outer loop) has a time-delay. Two different approaches, including an autotuning method, to find the controller parameters are proposed.

It is shown by some examples that the proposed structure as expected can provide better performance than conventional cascade control, a Smith predictor scheme or single feedback control system.

Free Bonus: To read the full article on using cascade control and a Smith predictor, click here.

ISA membership entitles you to free access to all ISA Transactions articles plus a wealth of technical content, industry information, free webinars, training opportunities, program discounts, certification and licensure and professional networking.

Join ISA ... learn, advance, succeed!

Advertisement

Trending Articles

Advertisement

Related Articles

View all Articles and News
Advertisement
Advertisement