• ISA provides technical resources and standards to help industrial automation professionals advance their careers and the field. We enable automation professionals worldwide to solve problems and enhance their skills by bringing people together to create new technologies and share best practices with future automation professionals.
    • Industry Insights

  • We attract over 140,000 unique automation professionals monthly, making us the premier online content provider and the only dedicated electronic magazine in the automation industry.

    Monthly Magazine

    • More things to read

    Back
    Back
  • M logo for Automation.com Monthly. Link to current issue.

ITT introduces packer feedthru system for downhole cables

08 October, 2009
ITT introduces packer feedthru system for downhole cables
ITT introduces packer feedthru system for downhole cables
Providing a faster method of passing power cables through packers, the system has a field-attachable feedthru connector, a mating attachable cable connector, and a cross-over adapter.

October 8, 2009 – ITT Interconnect Solutions announced the field-attachable packer feedthru system. Providing a faster method of passing power cables through packers, the packer feedthru system has a field-attachable feedthru connector, a mating attachable cable connector, a cross-over adapter and accompanying hardware.The feedthru system allows the connector to be installed on the top side of a packer using a cross-over adapter, eliminating the need to splice downhole cables. This in turn eliminates any potential stress on the cable, as the packer feedthru system includes a completely variable threaded adjustment system.The variable threaded system allows vertical adjustment of up to three inches (76mm).

It’s also possible to install the termination contacts on the cable conductors before the cable is passed through the packer, potentially reducing the amount of work an installer is required to carry out in a vertical position over an open well.The field-attachable packer feedthru system has a maximum diameter of 2.6 inches (66.04mm).

Length above the packer with a round cable ranges from 26.4 to 29.5 inches (672mm to 748mm), while length with a flat cable ranges from 30.4 to 33.4 inches (772mm to 848mm).

Voltage rating is to 5,000VAC, with current to 140A and pressure to 5,000psig. Maximum conductor temperature is 175°C (350°F).