• ISA provides technical resources and standards to help industrial automation professionals advance their careers and the field. We enable automation professionals worldwide to solve problems and enhance their skills by bringing people together to create new technologies and share best practices with future automation professionals.
    • Industry Insights

  • We attract over 140,000 unique automation professionals monthly, making us the premier online content provider and the only dedicated electronic magazine in the automation industry.

    Monthly Magazine

    Back
    Back
  • M logo for Automation.com Monthly. Link to current issue.

NK Technologies introduces DS1 DC Current Sensors

Source: NK Technologies
07 January, 2013
NK Technologies introduces DS1 DC Current Sensors
NK Technologies introduces DS1 DC Current Sensors
DS1 current sensors feature deliver reliable detection of very low DC current levels in a wide range of applications.

January 7, 2013 - NK Technologies introduces DS1 DC Current Sensors. The sensors feature a compact and non-adjustable one-piece design to deliver reliable detection of very low DC current levels in a wide range of applications. Their compact and non-adjustable one-piece design simplifies installation, even in crowded control cabinets. DS1 current sensors can be powered by any DC voltage between 10-28 volts and use the same circuit as the one being controlled, or a separate source of voltage to power the sensor as long as the circuit being controlled uses the same ground. This further simplifies installation and operation when compared with other current sensors.

Not only can the DS1 provide instant indication of equipment status, it can be used as a non-intrusive safety interlock method to keep personnel safe, as an alarm contact to indicate when a load is operating or when it is not energized and as a means to detect PV system leakage by monitoring the earth bond conductor. The DS1’s contact can even be used to turn on a lighting circuit when a load is energized. With the DS1, a solid state contact closes the output when there is current as low as 0.75 amps DC, and opens when there is no current. The contact can control a DC load up to one amp, up to 30 VDC.

NK Technologies offers no-cost test and evaluation units to qualifying OEMs. Visit the Engineering Resources section of NK Technologies website for access to numerous application notes and a technology white paper on current sensing technology.

Trending Articles

Advertisement

Related Industry Products

View all Industry Products
Advertisement
Advertisement