• ISA provides technical resources and standards to help industrial automation professionals advance their careers and the field. We enable automation professionals worldwide to solve problems and enhance their skills by bringing people together to create new technologies and share best practices with future automation professionals.
    • Industry Insights

  • We attract over 140,000 unique automation professionals monthly, making us the premier online content provider and the only dedicated electronic magazine in the automation industry.

    Monthly Magazine

    • More things to read

    Back
    Back
  • M logo for Automation.com Monthly. Link to current issue.

Roalan announces NetCom Serial Device Servers with PoE

07 October, 2012
Roalan announces NetCom Serial Device Servers with PoE
Roalan announces NetCom Serial Device Servers with PoE
NetCom 111 PoE, 113 PoE and 211 PoE Serial Device Servers are powered over the Ethernet connection.

October 7, 2012 - Roalan announces Serial Device Servers, powered over the Ethernet connection. In such an installation an Ethernet switching Hub with PoE option inserts the supply currents onto the network cable, the NetCom Servers use this to operate. If the external power adapter is installed in parallel, this operates as an auxiliary power supply. The source of electric power is completely transparent to any software, application or configuration tool. The models may be used as drop-in replacements of existing devices in already running installations.

Using a supply via the LAN cable eliminates the need to create an extra AC or DC power line to the location of the device. Of course in all installations there is some kind of supply at the location, at least to run the connected serial equipment. But this may be a low power supply, run from battery, or also the distance to the Serial Device Server may be significant when using RS422. Further the serial device might draw power from the serial port (RS232 or RS422), this also is an ideal occasion to use Power over Ethernet. Power over Ethernet: Such functions have been in development since a long time.

The wish to use one cable only instead of separate data and power cables resulted in some proprietary solutions. In 2003 the Internet Engineering Task Force created the first official version of a standard, now known as IEEE-802.3af-2003. This provides roughly 13W of electric power from a Power Sourcing Equipment (PSE) to a Powered Device (PD).

The power is applied after sensing whether a 802.3af compliant device is connected to the LAN cable. The PSE usually is an Ethernet Switch with added capabilities for PoE function, but sometimes special Power Inserters are installed. In the same way, the power may be extracted by a so-called PoE Splitter at the device location. "Power over Ethernet" is nicknamed as PoE, and in general also refers to the old and proprietary methods as well.

But today without a special reference it is used for the IEEE standard only. Those PoE sources provide roughly 13W to a PD, and in some installations the PD may use up to 15W of electric power. In 2009 the newer standard named IEEE-802.3at-2009 was finished. This new standard is also referenced as "PoE plus" or "PoE+" for short.

Advertisement

There is no known ambiguity with proprietary standards, so this nickname only refers to the 802.3at version. A PD can declare itself as a member of a certain power class, defined as 'Very Low power' (<3.9W), 'Low power' (<6.5W), 'Mid power' (<13W) and 'High power' (<25W).

The last class is only available in PoE+ installations. Announcing the power class to the PSE (the Switch) allows the PSE to optimize the power budget for all Ethernet ports and the connected PDs. top Power Class: The new NetCom PoE Serial Device Servers are Class 2 (Low Power) devices. The maximum consumption is up to 3W in NetCom 211 PoE, while for Class 2 the PSE allows up to 6.5W of electric power.

The NetCom 111 PoE and 113 PoE use even less power. In principle they are Class 1 (Very Low Power) devices. The Class 2 has been choosen to cover difficult connections (long cables, higher resistance, …), where the power draw may be slightly above the maximum 3.85W for Class 1. In most installations it is save to apply a Class 1 limit at the PSE (Ethernet Switch).

The supply via the Ethernet cable has precedence over an external power adapter, users may install an additional local power adapter as auxiliary or backup supply. However if the PSE fails to power the NetCom, it is likely the Ethernet connection fails as well. So this may be an option for test environments, but not used in productive installations.