By Jean Carl, Macro Sensors
By Jean Carl, Macro Sensors
With improved stroke to length ratio (now up to 80%), the LVDT Linear Position Sensor becomes a viable position measurement device for hydraulic cylinder positioning.
The development of computerized layer winding and improved microprocessing has considerably reduced the body length of the linear position sensor compared to its measurable stroke length. With the improved stroke to length ratio (now up to 80%), the LVDT Linear Position Sensor becomes a viable position measurement device for hydraulic cylinder positioning.
The role of the cylinder in most hydraulic applications is to move “something” such as a valve, airplane tail rudder, or a boom or shovel on an off-road vehicle. In these applications, the control system needs a feedback device that tells it how far the cylinder or actuator moved to ensure proper operations. That’s where the linear position sensor comes in. Installed within or outside the cylinder, the LVDT tracks the movement of actuators and reports data electronically to a control system that can monitor and provide alerts on operating conditions.
For example, if a pilot wants to turn the plane, he moves the joystick. The plane’s control system senses that he has moved the joy stick and sends a signal to the tail rudder actuator to move the tail rudder. If the system has no way of knowing how far the actuator has moved through position feedback provided by an LVDT linear position sensor, the plane could turn too much or not enough.
A second example would be a robotic arm. In this scenario, let’s say the robotic arm is going to move to pick up a piece of glass. If the control system does not know when to stop the arm by receiving position feedback from an LVDT position sensor, the hydraulic cylinder could drive the arm right through the piece of glass.
Care should be taken in choosing the right LVDT linear position for an application. While miniature LVDTs are suitable for high response dynamic measurement, hermetically sealed LVDTs are ideal for environments that experience high pressure wash down, humidity, dust and in some cases submersion.
Many modern LVDTs can serve as cost effective replacements to magnetostrictive technology that are somewhat expensive in shorter ranges, have difficulty handling large shocks and exhibit good temperature stability over a limited temperature range.
The following chart compares the characteristics of LVDT linear position sensor to magnetostrictive technology in different ranges.
Characteristics |
AC-operated LVDTs |
DC-operated LVDTs |
Magnetostrictive |
Magnetostrictive |
Range |
0.02 – 20”(0.5-500mm) |
0.1 – 20”(2.5-500mm) |
0.1 – 20”(2.5-500mm) |
6 – 120”(0.15-3.0m) |
Accuracy |
Very Good |
Very Good |
Good |
Excellent |
Resolution |
Excellent |
Excellent |
Good |
Excellent |
Repeatability |
Excellent |
Excellent |
Good |
Excellent |
Temperature Resistance |
Excellent |
Moderate |
Fair |
Good |
Linearity |
Good |
Good |
Good |
Very Good |
Cost |
Moderate |
High |
High |
High |
Complexity of Support Electronics |
Moderate |
Low |
Low |
Low |